2-parts assemble unit futura

2-part assemble unit Futura Size 0 G1/4
Description2 part service unit assemble of : filter-regulator and lubricator
ConnectionG 1/4"
Working mediumCompressed air, neutral gases
Operating positionVertical, drain plug at the bottom
Working temperature Max. 50°C
Operating pressure rangeMax. 12 bar; min. 1,5 bar
Filtering5 um standard
Tank volumeMax. 16 cm3 filter 35 cm3 lubricator
Pressure regulation range0,5-8 bar standard; 0,2-4 bar; 0,5-10 bar
Oil metering10-20 drops /min
Recommended oilPneumatikol UPM
Flow600 l/min
Weight0,386 kg
Order no. Thread Option
PNKS2U-014/4 G G 1/4" Manual condensate discharge
PNKS2U-014/4 AM G G 1/4" Automatic condensate discharge
PNKS2U-014/8 G G 1/4" Manual condensate discharge
PNKS2U-014/8 AM G G 1/4" Automatic condensate discharge
PNKS2U-014/10 G G 1/4" Manual condensate discharge
PNKS2U-014/10 AM G G 1/4" Automatic condensate discharge

2-part assemble unit Futura Size I G1/4
Description2 part service unit assemble of : filter-regulator and lubricator
ConnectionG 1/4"
Working mediumCompressed air, neutral gases
Operating positionVertical, drain plug at the bottom
Working temperature Max. 50°C
Operating pressure rangeMax. 16 bar; min. 1,5 bar
Filtering5 um standard
Tank volumeMax. 28 cm3 filter ; 40 cm3 lubricator
Pressure regulation range0,5-8 bar standard; 0,1-1 bar; 0,1-2 bar; 0,2-4 bar; 0,5-10 bar; 0,5-16 bar
Oil metering1 - 2 drops /min
Recommended oilPneumatikol UPM
Flow1800 l/min
Weight0,673 kg
Order no. Thread Option
PNKS2U-114/1 G G 1/4" Manual condensate discharge
PNKS2U-114/1 AM G G 1/4" Automatic condensate discharge
PNKS2U-114/2 G G 1/4" Manual condensate discharge
PNKS2U-114/2 AM G G 1/4" Automatic condensate discharge
PNKS2U-114/4 G G 1/4" Manual condensate discharge
PNKS2U-114/4 AM G G 1/4" Automatic condensate discharge
PNKS2U-114/8 G G 1/4" Manual condensate discharge
PNKS2U-114/8 AM G G 1/4" Automatic condensate discharge
PNKS2U-114/10 G G 1/4" Manual condensate discharge
PNKS2U-114/10 AM G G 1/4" Automatic condensate discharge
PNKS2U-114/16 G G 1/4" Manual condensate discharge
PNKS2U-114/16 AM G G 1/4" Automatic condensate discharge

2-part assemble unit Futura Size I G3/8
Description2 part service unit assemble of : filter-regulator and lubricator
ConnectionG 3/8"
Working mediumCompressed air, neutral gases
Operating positionVertical, drain plug at the bottom
Working temperature Max. 50°C
Operating pressure rangeMax. 16 bar; min. 1,5 bar
Filtering5 um standard
Tank volumeMax. 28 cm3 filter 40 cm3 lubricator
Pressure regulation range0,5-8 bar standard; 0,1-1 bar; 0,1-2 bar; 0,2-4 bar; 0,5-10 bar; 0,5-16 bar
Oil metering1 - 2 drops /min
Recommended oilPneumatikol UPM
Flow1800 l/min
Weight0,647 kg
Order no. Thread Option
PNKS2U-138/1 G G 3/8" Manual condensate discharge
PNKS2U-138/1 AM G G 3/8" Automatic condensate discharge
PNKS2U-138/2 G G 3/8" Manual condensate discharge
PNKS2U-138/2 AM G G 3/8" Automatic condensate discharge
PNKS2U-138/4 G G 3/8" Manual condensate discharge
PNKS2U-138/4 AM G G 3/8" Automatic condensate discharge
PNKS2U-138/8 G G 3/8" Manual condensate discharge
PNKS2U-138/8 AM G G 3/8" Automatic condensate discharge
PNKS2U-138/10 G G 3/8" Manual condensate discharge
PNKS2U-138/10 AM G G 3/8" Automatic condensate discharge
PNKS2U-138/16 G G 3/8" Manual condensate discharge
PNKS2U-138/16 AM G G 3/8" Automatic condensate discharge

2-part assemble unit Futura Size II G3/8
Description2 part service unit assemble of : filter-regulator and lubricator
ConnectionG 3/8"
Working mediumCompressed air, neutral gases
Operating positionVertical, drain plug at the bottom
Working temperature Max. 50°C
Operating pressure rangeMax. 16 bar; min. 1,5 bar
Filtering5 um standard
Tank volumeMax. 49 cm3 filter ; 80 cm3 lubricator
Pressure regulation range0,5-8 bar standard; 0,1-1 bar; 0,1-2 bar; 0,2-4 bar; 0,5-10 bar; 0,5-16 bar
Oil metering1 - 2 drops /min
Recommended oilPneumatikol UPM
Flow3500 l/min
Weight1,099 kg
Order no. Thread Option
PNKS2U-238/1 G G 3/8" Manual condensate discharge
PNKS2U-238/1 AM G G 3/8" Automatic condensate discharge
PNKS2U-238/2 G G 3/8" Manual condensate discharge
PNKS2U-238/2 AM G G 3/8" Automatic condensate discharge
PNKS2U-238/4 G G 3/8" Manual condensate discharge
PNKS2U-238/4 AM G G 3/8" Automatic condensate discharge
PNKS2U-238/8 G G 3/8" Manual condensate discharge
PNKS2U-238/8 AM G G 3/8" Automatic condensate discharge
PNKS2U-238/10 G G 3/8" Manual condensate discharge
PNKS2U-238/10 AM G G 3/8" Automatic condensate discharge
PNKS2U-238/16 G G 3/8" Manual condensate discharge
PNKS2U-238/16 AM G G 3/8" Automatic condensate discharge

2-part assemble unit Futura Size II G1/2
Description2 part service unit assemble of : filter-regulator and lubricator
ConnectionG 1/2"
Working mediumCompressed air, neutral gases
Operating positionVertical, drain plug at the bottom
Working temperature Max. 50°C
Operating pressure rangeMax. 16 bar; min. 1,5 bar
Filtering5 um standard
Tank volumeMax. 49 cm3 filter; 80 cm3 lubricator
Pressure regulation range0,5-8 bar standard; 0,1-1 bar; 0,1-2 bar; 0,2-4 bar; 0,5-10 bar; 0,5-16 bar
Oil metering1 - 2 drops /min
Recommended oilPneumatikol UPM
Flow3500 l/min
Weight1,057 kg
Order no. Thread Option
PNKS2U-212/1 G G 1/2" Manual condensate discharge
PNKS2U-212/1 AM G G 1/2" Automatic condensate discharge
PNKS2U-212/2 G G 1/2" Manual condensate discharge
PNKS2U-212/2 AM G G 1/2" Automatic condensate discharge
PNKS2U-212/4 G G 1/2" Manual condensate discharge
PNKS2U-212/4 AM G G 1/2" Automatic condensate discharge
PNKS2U-212/8 G G 1/2" Manual condensate discharge
PNKS2U-212/8 AM G G 1/2" Automatic condensate discharge
PNKS2U-212/10 G G 1/2" Manual condensate discharge
PNKS2U-212/10 AM G G 1/2" Automatic condensate discharge
PNKS2U-212/16 G G 1/2" Manual condensate discharge
PNKS2U-212/16 AM G G 1/2" Automatic condensate discharge

2-part assemble unit Futura Size III G3/4
Description2 part service unit assemble of : filter-regulator and lubricator
ConnectionG 3/4"
Working mediumCompressed air, neutral gases
Operating positionVertical, drain plug at the bottom
Working temperature Max. 50°C
Operating pressure rangeMax. 16 bar; min. 1,5 bar
Filtering5 um standard
Tank volumeMax. 87 cm3 filter; 181 cm3 lubricator
Pressure regulation range0,5-8 bar standard; 0,1-1 bar; 0,1-2 bar; 0,2-4 bar; 0,5-10 bar; 0,5-16 bar
Oil metering1 - 2 drops/min
Recommended oilPneumatikol UPM
Flow12000 l/min
Weight1,897 kg
Order no. Thread Option
PNKS2U-434/1 G G 3/4" Manual condensate discharge
PNKS2U-434/1 AM G G 3/4" Automatic condensate discharge
PNKS2U-434/2 G G 3/4" Manual condensate discharge
PNKS2U-434/2 AM G G 3/4" Automatic condensate discharge
PNKS2U-434/4 G G 3/4" Manual condensate discharge
PNKS2U-434/4 AM G G 3/4" Automatic condensate discharge
PNKS2U-434/8 G G 3/4" Manual condensate discharge
PNKS2U-434/8 AM G G 3/4" Automatic condensate discharge
PNKS2U-434/10 G G 3/4" Manual condensate discharge
PNKS2U-434/10 AM G G 3/4" Automatic condensate discharge
PNKS2U-434/16 G G 3/4" Manual condensate discharge
PNKS2U-434/16 AM G G 3/4" Automatic condensate discharge

2-part assemble unit Futura Size III G1
Description2 part service unit assemble of : filter-regulator and lubricator
ConnectionG 1"
Working mediumCompressed air, neutral gases
Operating positionVertical, drain plug at the bottom
Working temperature Max. 50°C
Operating pressure rangeMax. 16 bar; min. 1,5 bar
Filtering5 um standard
Tank volumeMax. 87 cm3 filter; 181 cm3 lubricator
Pressure regulation range0,5-8 bar standard; 0,1-1 bar; 0,1-2 bar; 0,2-4 bar; 0,5-10 bar; 0,5-16 bar
Oil metering1 - 2 drops/min
Recommended oilPneumatikol UPM
Flow12000 l/min
Weight1,763 kg
Order no. Thread Option
PNKS2U-41/1 G G 1" Manual condensate discharge
PNKS2U-41/1 AM G G 1" Automatic condensate discharge
PNKS2U-41/2 G G 1" Manual condensate discharge
PNKS2U-41/2 AM G G 1" Automatic condensate discharge
PNKS2U-41/4 G G 1" Manual condensate discharge
PNKS2U-41/4 AM G G 1" Automatic condensate discharge
PNKS2U-41/8 G G 1" Manual condensate discharge
PNKS2U-41/8 AM G G 1" Automatic condensate discharge
PNKS2U-41/10 G G 1" Manual condensate discharge
PNKS2U-41/10 AM G G 1" Automatic condensate discharge
PNKS2U-41/16 G G 1" Manual condensate discharge
PNKS2U-41/16 AM G G 1" Automatic condensate discharge

Offer

The Design Departament

Dział projektowy HAFNER PNEUMATYKA

General Pneumatics

General informations about pneumatics

A Reliable company

Rzetelna firma HAFNER

General trade conditions

HAFNER Pneumatyka

ABOUT US

HAFNER
Pomagier-Trzebuchowscy
sp. z o.o.
ul. Marii Skłodowskiej-Curie 97
87-100 Toruń

NIP 556-22-23-819
Regon 092307860
KRS 0000154149

Santander Bank Polska SA

79 10901069 0000 0000 0704 8941

Bank account ING Bank Śląski

64 10501139 1000 0023 4975 0618

CSP

Fundusz Europejski

Fundusz Europejski

News

We have become part of the Rubix Group

We have become part of the Rubix Group

Hafner w czasie pandemii

Hafner w czasie pandemii

Generatory azotu

Siłowniki dla hutnictwa

Siłowniki pneumatyczne WSRK

CSP

Centrum Serwisowo Projektowe

Cylinders production

Produkcja siłowników 24h

Order our catalogue

Zamów katalog PNEUMATYKA